infinitedaa.blogg.se

Crestron xpanel not working
Crestron xpanel not working













crestron xpanel not working

tokenSource and tokenUrl should not be changed, as they are provided to ensure forward compatibility with future identity provider services.Ĭhange XPanel Connection Parameters via URLĪll the parameters described in prior sections ( host, ipId, roomId, port, and licenseExpirationWarning) can be provided as URL parameters to allow a single project to be used for multiple systems with different parameters.port: Change only if the control system SECUREWEBSocketport parameter was changed from its default value or a port forwarding rules are in effect.

crestron xpanel not working

Set to "0" to disable the expiration warning message. Use this parameter to change the number of days before this warning is shown. licenseExpirationWarning: A warning message can be shown a set number of days before a Mobility license or a license trial period will expire.This parameter is applicable only for VC-4 deployments. The default value is the Room ID in the Web XPanel URL provided by VC-4 (/VirtualControl//XPanel). roomId: The Crestron Virtual Control (VC-4) Room ID.ipId: The IP ID of the control system program.

crestron xpanel not working

The default value is the same domain as the Web XPanel URL. It can be provided as a host name, FQDN (fully qualified domain name), or an IP address. Refer to Change XPanel Connection Parameters via URL. It is even below IPID 10, and xpanel is a first party product so the whole hex/dec conversion that can happen with 3rd party devices above IPID 10 should not be an issue.Ĭould this be a certificate issue? I don't know what the symptoms would be of a bad cert, but I would think if it was a CA issue I wouldn't even see the xpanel project at all when connecting to that IP.NOTE: The parameters provided in the config/controlSystem object will be overwritten when the same parameter is proved as a URL parameter. The symptoms do go along with an incorrect IPID, but it is the correct IPID. Where do I go from here? As I stated I did contact Crestron for support and the response was "everything looks good and it should work".Įdit: standard xpanels work just fine.

crestron xpanel not working

It is a DMPS3-300-C and I tried the "core3xpanelweb" commend in the console for more info but it came back as an invalid command. I can connect to the ip address of the processor and it does load the xpanel project but it never actually connects with the control system (showing as offline in toolbox, and none of the smart graphics are loading). In VTPro I have the host connection set to the loopback IP ( 127.0.0.1), the ipid is set to match the xpanel defined in my program, and I the port is set to 41794 (I have also tried 4176 as I do have authentication turned on but changing ports did not help). I am trying to host web xpanels on my processors but I am having some issues, I have talked to Crestron support and they said everything is configured properly so it should work.